Determine the existing or planned building elements including structural.
Usg fire rated ceiling assemblies.
Our range of drawings can help pros plan projects more effectively by utilizing designs for a fire rated ceiling assembly.
Refer to the material safety data sheet for each product for complete health and safety information.
12 x 24 2 x 4 8 w10 x 25 beam floor units and beam support 3 hr.
Floor ceiling assemblies ceiling system lighting hvac outlets and other penetrants through the ceiling the plenum structural system subfloor and finish floor.
Access our all new collection of sound tested fire rated wall assemblies.
Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system.
276 fire rated ceiling assemblies suspension ceiling designs floor ceiling designs a003 3 hr.
Estimate materials and find usg equivalents for your building projects.
Establish the hourly rating needed to meet code requirements.
Selecting the right ul fire rated assembly.
7 usg acoustical assemblies components acoustically rated systems have been comprehensively tested for sound control.
Here you can find drawings for our ul fire rated floor assemblies and ul fire rated ceiling assemblies.
Concrete with cellular steel 3 hr.
Find the right fire rated assemblies and design details drawings for your architectural plans.
Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies.
3 4 fr 83 12 x 12 z runners fluorescent type none 2 1 2 concrete.
The use and location of insulation in the assembly can dramatically affect fire performance because insulation traps heat even if it is being used for sound purposes and can cause premature failure.
Usg panels usg panels usg panels ul design number ul design number ul design number g503 g531 l501 l508 n501 n502 n505 p515 p516.
It is important to note that insulation cannot be arbitrarily added to a fired rated floor ceiling assembly that was tested without insulation.
7 usg fire resistant assemblies cross reference of usg panels and ul fire ratings the following table lists the usg panels that are appropriate to use for different ul fire resistive designs.
Urb concealed grid system and tile.